Victron Skylla‑TG Battery Chargers (24 V & 48 V)

Free shipping over $49

60-day hassle-free returns
The Skylla‑TG is Victron’s classic, no‑nonsense high‑current charger line—ideal for blue‑water cruisers, commercial vessels, and industrial DC systems. A microprocessor‑controlled IUoUo 3‑stage algorithm charges fast while protecting your batteries, and the metal IP21 chassis with forced‑air cooling is made to run hard in hot engine rooms. With adjustable set‑points, temperature compensation, and remote voltage‑sense at the terminals, Skylla‑TG delivers the accuracy your battery manufacturer expects.
Why boat owners choose Skylla‑TG
-
Serious output for large banks: 24 V models in 30/50/80/100 A; 48 V models in 25/50 A.
-
House + starter coverage (24 V): Most 24 V models provide a full‑rated house output plus a 4 A isolated auxiliary to maintain a start battery. (48 V models are single‑output; 24/100 3‑phase is single‑output.)
-
Precision battery care: Fully adjustable absorption/float voltages, temperature‑compensation (sensor included), and remote voltage‑sense for true at‑battery regulation.
-
Power‑supply capable: Stabilized DC output lets Skylla‑TG work as a bench/ship’s supply when the battery is offline.
-
Flexible input options: Select single‑phase 120/230 VAC and 230 VAC, or 3×400 VAC models; most single‑phase variants also accept high‑voltage DC input for AC‑DC or DC‑DC operation.
-
Marine‑ready build: IP21 aluminum enclosure, forced cooling, and wide operating range (−40 to 122 °F) keep you online in harsh conditions.
-
Alarm & control: Potential‑free alarm contacts and remote on/off via an optional switch/panel.
Skylla‑TG GMDSS (24 V) — purpose‑built for distress & safety systems
Designed to simplify compliance, the GMDSS versions provide all required monitoring and alarms without extra boxes. Both the battery and the DC load connect directly to the charger; status and alarms show on a digital GMDSS panel (ordered separately) over a simple UTP cable. A built‑in controller even estimates “time‑to‑go” during a mains outage—exactly what a watch‑stander needs.
Available models
Skylla‑TG (standard)
-
24/30 TG — 30 A: 120/230 VAC (95–264 VAC); also accepts 120–400 VDC input; includes 4 A starter‑battery auxiliary.
-
24/50 TG — 50 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
-
24/50 TG 3‑phase — 50 A: 3×400 VAC (320–450 VAC); includes 4 A starter auxiliary.
-
24/80 TG — 80 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
-
24/100 TG — 100 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
-
24/100 TG 3‑phase — 100 A: 3×400 VAC (320–450 VAC); single‑output (no 4 A auxiliary).
-
48/25 TG — 25 A: 230 VAC (185–264 VAC); 180–400 VDC input; single‑output.
-
48/50 TG — 50 A: 230 VAC (185–264 VAC); 180–400 VDC input; single‑output.
Skylla‑TG GMDSS (24 V)
-
24/30 GMDSS — 30 A: 120/230 VAC (90–265 VAC). (Output limited to 22 A at 110 VAC.)
-
24/50 GMDSS — 50 A: 120/230 VAC (90–265 VAC).
Specifications vary by model (dimensions, weight, and connection details). Refer to the datasheets for full mechanical and electrical data.
Technical snapshot
-
Charge algorithm: IUoUo (3‑stage) with adjustable set‑points; can be used as a stabilized DC power supply.
-
Two outputs (most 24 V models): full‑rated house output + 4 A isolated starter‑battery maintainer; 48 V and 24/100 3‑phase are single‑output.
-
Input flexibility: single‑phase 120/230 VAC, 230 VAC, or 3×400 VAC depending on model; most single‑phase units accept high‑voltage DC input (~120–400 VDC).
-
Operating temp: −40 to 122 °F; IP21 enclosure; forced‑air cooling; potential‑free alarm contacts.
-
GMDSS versions: built‑in monitoring/alarms with time‑to‑go readout via the dedicated remote panel.
Sizes & weight (examples)
-
24/30 A: ≈ 14.4 × 9.9 × 5.8 in, 12.1 lb
-
24/50 A: ≈ 14.4 × 9.9 × 10.1 in, 28 lb
-
24/80 A: ≈ 20.0 × 10.2 × 10.4 in, 22 lb
-
24/100 A: ≈ (varies by version), ~48 lb
-
GMDSS 24/30–24/50 A: ≈ 19.1 × 9.9 × 5.8 in, 13 lb
Installation notes
Mount vertically in a ventilated space to support forced‑air cooling. Use appropriately sized cabling and fusing; land voltage‑sense leads directly at the battery terminals and install the temperature sensor on a representative battery. For lithium banks, set charge voltages to your battery maker’s spec and wire the remote on/off through the BMS dry‑contact or a control relay.
Warranty Information
Shipping & Returns
We offer free shipping over $49. Lithium batteries & oversize items may have an applicable shipping charge.
We know returns are no fun so we aim to make the return process as hassle free as possible! We have a 60-day return policy, which means you have 60 days after receiving your item to request a return.
Lithium batteries and products with lithium batteries inside are non returnable: Due to carrier regulations surrounding the shipment of lithium batteries (classified as a fully regulated hazardous material), we are unable to accept returns unless arranged locally. We appreciate your understanding and encourage you to contact us with any questions prior to purchase.
For more information on returns, visit our return policy page.
Product Attachments
Choose options









About Blue Marine
Nationwide Shipping from Our Warehouse in Seattle
Knowledgeable technicians, firendly advice and fast shipping.