Victron Energy Skylla-TG Battery Charger (24V & 48V, 25-100A)
Free shipping over $49
60-day hassle-free returns
The Skylla-TG is Victron's classic, no-nonsense high-current charger line — ideal for blue-water cruisers, commercial vessels, and industrial DC systems. A microprocessor-controlled IUoUo 3-stage algorithm charges fast while protecting your batteries, and the metal IP21 chassis with forced-air cooling is made to run hard in hot engine rooms. With fully adjustable set-points, temperature compensation, and remote voltage-sense at the terminals, the Skylla-TG delivers the accuracy your battery manufacturer expects.
Why boat owners choose Skylla-TG
Serious output for large banks: 24 V models in 30 / 50 / 80 / 100 A; 48 V models in 25 / 50 A.
House + starter coverage (24 V): Most 24 V models provide a full-rated house output plus a 4 A isolated auxiliary to maintain a start battery. (48 V models and the 24/100 3-phase are single-output.)
Precision battery care: Fully adjustable absorption/float voltages, temperature compensation (sensor included), and remote voltage-sense for true at-battery regulation.
Power-supply capable: Stabilized DC output lets the Skylla-TG work as a bench or ship's supply when the battery is offline.
Flexible input options: Choose single-phase 120/230 VAC or 230 VAC, or 3×400 VAC models; every single-phase variant also accepts high-voltage DC input (~120–400 VDC) for AC-DC or DC-DC operation.
Marine-ready build: IP21 aluminium enclosure, forced cooling, and a wide operating range (−40 to 122 °F) keep you online in harsh conditions.
Alarm & control: Potential-free alarm contacts and remote on/off via an optional Skylla Control panel or switch.
Skylla-TG GMDSS (24 V) — purpose-built for distress & safety systems
Designed to simplify compliance, the GMDSS versions provide all required monitoring and alarms without extra boxes. Both the battery and the DC load connect directly to the charger; status and alarms show on a digital GMDSS panel (ordered separately) over a simple UTP cable. A built-in controller even estimates “time-to-go” during a mains outage — exactly what a watch-stander needs.
Available models
Skylla-TG (standard)
24/30 TG — 30 A: 120/230 VAC (95–264 VAC); also accepts 120–400 VDC input; includes 4 A starter-battery auxiliary.
24/50 TG — 50 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
24/50 TG 3-phase — 50 A: 3×400 VAC (320–450 VAC); includes 4 A starter auxiliary.
24/80 TG — 80 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
24/100 TG — 100 A: 230 VAC (185–264 VAC); 180–400 VDC input; includes 4 A starter auxiliary.
24/100 TG 3-phase — 100 A: 3×400 VAC (320–450 VAC); single-output (no 4 A auxiliary).
48/25 TG — 25 A: 230 VAC (185–264 VAC); 180–400 VDC input; single-output.
48/50 TG — 50 A: 230 VAC (185–264 VAC); 180–400 VDC input; single-output.
Skylla-TG GMDSS (24 V)
24/30 GMDSS — 30 A: 120/230 VAC (90–265 VAC). (Output limited to 22 A at 110 VAC.)
24/50 GMDSS — 50 A: 120/230 VAC (90–265 VAC).
Technical snapshot
Charge algorithm: IUoUo 3-stage with fully adjustable set-points (absorption 28.5 V / float 26.5 V on 24 V models; 57 V / 53 V on 48 V); also works as a stabilized DC power supply.
Outputs: most 24 V models = full-rated house output + 4 A isolated starter maintainer; 48 V and 24/100 3-phase = single-output.
Input: single-phase 120/230 VAC or 230 VAC, or 3×400 VAC depending on model; single-phase units also accept ~120–400 VDC. 45–65 Hz, power factor 1.
Operating temp: −40 to 122 °F; IP21 aluminium enclosure (blue RAL 5012); forced-air cooling.
Connections: M8 battery studs; potential-free alarm contacts (60 V / 1 A, 1× NO + 1× NC); remote on/off.
GMDSS versions: built-in monitoring/alarms with a “time-to-go” readout via the dedicated remote panel (sold separately).
Weight by model
24/30 and 48/25: ≈ 5.5 kg (12 lb)
24/50 3-phase, 24/80, and 48/50: ≈ 10 kg (22 lb)
24/50: ≈ 13 kg (28 lb)
24/100 and 24/100 3-phase: ≈ 23 kg (48 lb)
Three chassis sizes are used depending on output; refer to the model datasheet for exact mechanical dimensions.
Installation notes
Mount vertically in a ventilated space to support forced-air cooling. Use appropriately sized cabling and fusing; land the voltage-sense leads directly at the battery terminals and install the included temperature sensor on a representative battery. Because absorption and float voltages are fully adjustable, the Skylla-TG can be dialed in for flooded, AGM, or gel banks — and for lithium, set the voltages to your battery maker's spec and route BMS control through the remote on/off dry-contact.
Blue Marine tip: add a Victron BMV or SmartShunt battery monitor for accurate state-of-charge, and a Skylla Control panel if you want to limit input current on a small shore-power fuse or genset.
Warranty Information
Shipping & Returns
We offer free shipping over $49. Lithium batteries & oversize items may have an applicable shipping charge.
We know returns are no fun so we aim to make the return process as hassle free as possible! We have a 60-day return policy, which means you have 60 days after receiving your item to request a return.
Lithium batteries and products with lithium batteries inside are non returnable: Due to carrier regulations surrounding the shipment of lithium batteries (classified as a fully regulated hazardous material), we are unable to accept returns unless arranged locally. We appreciate your understanding and encourage you to contact us with any questions prior to purchase.
For more information on returns, visit our return policy page.