Victron Energy Lithium Battery Smart (LiFePO4) - 12.8V & 25.6V
Free shipping over $49
Lithium batteries & products containing lithium batteries are non returnable
The Victron Lithium Battery Smart is a LiFePO4 (lithium iron phosphate) battery with built-in Bluetooth, cell balancing, and cell monitoring - the building block of a modern marine, RV, or off-grid house bank. Available in 12.8V and 25.6V, in capacities from 100 Ah to 200 Ah, it can be wired in series, parallel, or series/parallel to build 12V, 24V, or 48V banks up to 20 batteries.
Important - this is a system battery, not a drop-in: Victron Lithium Smart batteries do not contain an internal BMS. They have integrated cell balancing and monitoring whose cables must connect to a separate Victron BMS, which protects the cells and disconnects loads or chargers on a cell over/under-voltage or temperature alarm. Choose a BMS to suit your system (see "Choosing a BMS" below) - we're glad to help you spec it.
Who it's built for
- Cruising boats and liveaboards - a deep, efficient house bank that tolerates partial charging and the constant cycling of life at anchor.
- RVs, vans, and overlanders - up to ~70% less weight and space than equivalent lead-acid, with usable capacity down to a deep discharge.
- Off-grid solar and backup - 92% round-trip efficiency and excellent shallow-cycle performance make the most of every solar amp-hour.
- System builders - pair with a Victron BMS, MultiPlus/Quattro inverter/charger, and SmartSolar MPPTs for a fully integrated, monitored system.
Why lithium iron phosphate, and why Smart
Rugged - thrives on partial charging
Unlike lead-acid, an LFP battery does not need to be fully recharged and isn't damaged by sitting partially charged - service life even improves slightly under partial charge. Add a wide operating temperature range, low internal resistance, and high efficiency, and LFP is the chemistry of choice for demanding marine and off-grid use.
Efficient and light
92% round-trip efficiency (vs ~80% for lead-acid, and far less in the upper state-of-charge range), and up to 70% savings in both space and weight versus an equivalent lead-acid bank.
Long cycle life
Rated for 2,500 cycles at 80% depth of discharge, 3,000 cycles at 70% DoD, and 5,000 cycles at 50% DoD (to 80% remaining capacity), with under 1% capacity loss per 100 cycles.
Built-in Bluetooth
Monitor individual cell voltages, temperature, and alarm status right in the free VictronConnect app - Instant Readout shows the key data on the device list without even connecting, which makes spotting a cell imbalance easy.
Integrated cell balancing and monitoring
Every battery has built-in balancing and monitoring; the daisy-chained M8 connector cables run to your Victron BMS, which handles protection and load/charge disconnection.
Scales to a real bank
Series, parallel, and series/parallel wiring builds 12V, 24V, or 48V banks - up to 20 batteries per BMS (up to ~102 kWh), and up to 5 BMS units paralleled. (For 48V, Victron recommends two 24V batteries in series over four 12V batteries to minimize balancing time.)
Available variants
All variants are sold on this page - choose your voltage and capacity from the variant selector above.
| Model | Nominal voltage | Capacity (25 C) | Energy | Max cont. discharge | Recommended charge | Weight |
|---|---|---|---|---|---|---|
| LFP Smart 12.8/100 | 12.8 V | 100 Ah | 1,280 Wh | 200 A | up to 50 A | 31 lb (14 kg) |
| LFP Smart 12.8/180 | 12.8 V | 180 Ah | 2,304 Wh | 360 A | up to 90 A | 40 lb (18 kg) |
| LFP Smart 12.8/200 | 12.8 V | 200 Ah | 2,560 Wh | 400 A | up to 100 A | 44 lb (20 kg) |
| LFP Smart 25.6/100 | 25.6 V | 100 Ah | 2,560 Wh | 200 A | up to 50 A | 62 lb (28 kg) |
| LFP Smart 25.6/200 | 25.6 V | 200 Ah | 5,120 Wh | 400 A | up to 100 A | 86 lb (39 kg) |
Not sure how to size your bank or which BMS to pair? Get a custom quote from our Seattle team or book a system consultation.
Choosing a BMS
These batteries require one of Victron's BMS units. A quick guide:
- SmallBMS (with pre-alarm) - 12, 24, or 48V systems without an inverter/charger.
- VE.Bus BMS V2 - 12, 24, or 48V systems with a MultiPlus/Quattro inverter/charger and a GX device.
- Lynx Smart BMS (500A or 1000A) - 12, 24, or 48V systems wanting digital integration and a built-in safety contactor to disconnect loads/inverters; common on yachts and RVs.
- Smart BMS CL 12/100 - 12V systems with an alternator.
- Smart BMS 12/200 - 12V systems with an alternator plus DC loads and an inverter/charger.
See all options on our Battery Management page, or call us and we'll match a BMS to your system.
Full technical specifications
Chemistry and performance
- Chemistry: Lithium Iron Phosphate (LiFePO4); 3.2 V nominal per cell (12.8V = 4 cells, 25.6V = 8 cells)
- Round-trip energy efficiency: 92%
- Cycle life: 2,500 (80% DoD), 3,000 (70% DoD), 5,000 (50% DoD), to >=80% capacity
- Capacity / energy loss: under 1% per 100 cycles (25 C, 100% DoD)
- Internal resistance: 0.8-1.6 mOhm by model
Charge and discharge
- Charge voltage: 14.2 V / 28.4 V recommended (range 14-14.4 V / 28-28.8 V)
- Float voltage: 13.5 V / 27 V
- End-of-discharge voltage: 11.2 V (12.8V) / 22.4 V (25.6V)
- Recommended charge current and max continuous discharge: see the variant table above
Operating conditions
- Operating temperature: discharge -20 C to +50 C; charge +5 C to +50 C (do not charge below freezing)
- Storage temperature: -45 C to +70 C; max storage time when fully charged: 1 year
- Humidity (non-condensing): 95% max
- Protection class: IP22
Connection and mounting
- BMS connection: male + female M8 circular-connector cable, 50 cm
- Power terminals: M8 threaded inserts
- Mounting: upright or on its side (never with terminals facing down)
- Max batteries per BMS: 20 (up to ~102 kWh); up to 5 BMS units in parallel
Standards
- Safety: cell/battery standards including UL 1973, IEC 62619, UL 9540A, IEC 62620 (varies by model); EN 60335-1, EN-IEC 62368-1, IEC 61427-1
- Automotive: ECE R10-6
Recommended accessories
- Victron BMS - required; SmallBMS, VE.Bus BMS V2, Lynx Smart BMS, or Smart BMS by system
- M8 circular-connector BMS cables - to extend the battery-to-BMS run
- Cerbo GX or Ekrano GX - whole-system monitoring via VRM
- SmartSolar MPPT and MultiPlus / Quattro inverter/chargers - lithium-ready charging
Installation and sizing help
A lithium bank needs the BMS, cabling, fusing, and charge sources all configured for LiFePO4 - including a charge profile that won't charge the battery below freezing. Two free resources to start with:
- Victron Wiring Unlimited - sizing the DC side of a Victron system.
- Lithium-ion vs lead-acid - how LFP compares.
If you want a second set of eyes on your bank and BMS choice, our certified technicians do system consultations and full custom quotes. Email support@bluemarine.com or call (800) 628-6306.
Frequently asked questions
Is this a drop-in lithium battery?
No. Victron Lithium Smart batteries are system batteries with no internal BMS - they require an external Victron BMS, which handles cell protection and disconnects loads/chargers on an alarm. This gives a more robust, fully monitored system than a self-contained drop-in, but it does mean the BMS and wiring are part of the install.
Which BMS do I need?
It depends on your system voltage and what's connected - see "Choosing a BMS" above. In short: SmallBMS for simple systems, VE.Bus BMS V2 for systems with a MultiPlus/Quattro and GX, Lynx Smart BMS for integrated systems wanting a safety contactor, and the Smart BMS CL 12/100 or 12/200 for 12V systems with an alternator.
Can I charge it in cold weather?
Charge only between +5 C and +50 C. Discharging is fine down to -20 C, but charging a lithium battery below freezing damages the cells - set your charge sources accordingly, and consider a temperature sensor in the system.
Can I build a 48V bank?
Yes. Wire batteries in series/parallel for 12V, 24V, or 48V. For 48V, Victron recommends two 25.6V batteries in series rather than four 12.8V batteries, to reduce balancing time.
What warranty does it come with?
A 3-year limited warranty from Victron Energy on lithium batteries (maximum 42 months from the Victron invoice date), per Victron's 2025 Limited Warranty Policy - note this is shorter than the 5-year warranty on Victron power products, and the 10-year extension does not apply to batteries. Warranty claims require proof of correct battery usage. Blue Marine handles the claim process - email support@bluemarine.com.
Why buy your Victron lithium battery from Blue Marine
- True Blue Victron Energy Distributor - genuine Victron batteries and BMS units, in stock.
- Certified technicians on the phone - (800) 628-6306 to spec your bank, BMS, and charging.
- Free shipping over $49 from our Seattle warehouse.
- 60-day hassle-free returns and local pickup in Seattle, WA.
- Custom quotes and full system design - we'll spec the battery, BMS, inverter/charger, MPPTs, cabling, and monitoring as one package.
Warranty Information
Shipping & Returns
We offer free shipping over $49. Lithium batteries & oversize items may have an applicable shipping charge.
We know returns are no fun so we aim to make the return process as hassle free as possible! We have a 60-day return policy, which means you have 60 days after receiving your item to request a return.
Lithium batteries and products with lithium batteries inside are non returnable: Due to carrier regulations surrounding the shipment of lithium batteries (classified as a fully regulated hazardous material), we are unable to accept returns unless arranged locally. We appreciate your understanding and encourage you to contact us with any questions prior to purchase.
For more information on returns, visit our return policy page.
Product Attachments
Choose options











About Blue Marine
Nationwide Shipping from Our Warehouse in Seattle
Knowledgeable technicians, firendly advice and fast shipping.